Product support
Spars fixed
SPAR # Description
1.194502162 - You cannot program a stapled booklet with more than 20 sheets if you have the Booklet Maker Finisher option (it should allow up to 25 sheets).
2.656473188 785326475 - You cannot select trays 1-4 for the Input Tray when calibrating or trays 6 or 7 if you have the Oversized High Capacity Feeder.
3.932742235 - Using CWS, you cannot program a job as booklets and no covers which can result in undesired blank pages when you do not want a cover.
NOTE: To program a job for booklet imposition and no cover, you program the job to print on both sides for front covers and print on any side for back cover.
NOTE: To program a job via print driver, you must also install driver patches 1 19UD02 (EFIGS) or 1 1ATFKH (Nordic) in addition to1.0SP1.
Following patches are obsolete now (they are included in sp1):
Patch Name Description
1 19QN74
(server side) - The document settings tab is not available in the driver properties.A conflict message occurs when you select 3 hole punch and double left staple.The Orientation Override option is missing in Command Workstation.
1 1A3P9W - Jobs submitted via driver to an LPR port do not show up in Command Workstation until the Fiery is rebooted.
1 1AFUGF - A 45-360 fault code occurs intermittently on some systems resulting in unnecessary replacement of the VSEL board.