When this patch is not installed even if the job is in black & white the 1st BTR's of the color stations CMY in the IOT are not retracted in B & W mode and the machine will keep the process control as it is in a full color job.
This leads to low toner in the developer tanks later when the customer is printing full color jobs afterwards.
When this patch is installed, if grayscale or Black & White jobs are sent the color stations CMY in the IOT are not retracted, it prints in k-only mode. The switch to
1. When pressing the sample button on the HCS the sample sheets number is as expected but when the jobs completes, it do not leaves the print queue, the status bar don’t clears from the DFE and remains at 98%.
2. The finished job in stacker is missing sheets.
When this patch is installed. It fixes issues 1 and 2
This patch will fix the issue of CWS displaying erroneous characters after patch 1-ZKLVP (patch for Hebrew servers) is installed on non-Hebrew servers.
Note: Your system must be at version EX700 v1.0_SP1 prior to installing this software.
This patch is for non-Hebrew Fiery’s only where patch 1-ZKLVP was installed unintentionally. On a non-Hebrew system with 1-ZKLVP installed, CWS will display corrupted characters. The user must install patch 1-ZVVZ6 and then jobs must be resubmitted for the correct characters to be displayed in CWS.
Caution: If 1-ZVVZ6 is installed on a Hebrew server accidentally, the user will have to reinstall patch 1-ZKLVP in order for the characters in CWS to display correctly.